首页 | 本学科首页   官方微博 | 高级检索  
     

电感耦合等离子体质谱法同时测定塑料食品接触材料原料和成型品中11 种元素溶出量
引用本文:陈旻实,郑洁,许才明,周雪晖,李小晶,郑思远,陈佳敏. 电感耦合等离子体质谱法同时测定塑料食品接触材料原料和成型品中11 种元素溶出量[J]. 食品科学, 2015, 36(8): 236-239. DOI: 10.7506/spkx1002-6630-201508044
作者姓名:陈旻实  郑洁  许才明  周雪晖  李小晶  郑思远  陈佳敏
作者单位:福建出入境检验检疫局检验检疫技术中心,国家消费品安全检测重点实验室,福建省检验检疫技术研究重点实验室,福建 福州 350003
基金项目:福建省科技计划重点项目(2014Y0001);国家质检总局科技计划项目(2013IK103)
摘    要:建立电感耦合等离子体质谱法同时测定铅(Pb)、镉(Cd)、铬(Cr)、砷(As)、汞(Hg)、锑(Sb)、锌(Zn)、锗(Ge)、镍(Ni)、硒(Se)和钡(Ba)11 种元素溶出量的方法。方法采用4%乙酸作为模拟液,在特定时间和温度条件下浸泡样品,浸泡液加入金稳定剂后过0.45 μm滤膜上样,质谱检测,内标法定量分析。在优化条件下,11 种元素在0.1~100 μg/L质量浓度范围内线性良好,相关系数均大于0.999。在低、中、高3 个水平进行添加实验,上述元素的平均回收率在97.5%~106.2%之间,重复性精密度在0.72%~2.76%(n=6)之间。结果表明,方法操作简单快速、重复性好、准确度高。

关 键 词:电感耦合等离子体质谱法  元素  溶出量  塑料  食品接触材料  

Simultaneous Determination of Eleven Elements Released from Plastic Food Contact Materials and Articles by Inductively Coupled Plasma-Mass Spectrometry
CHEN Minshi;ZHENG Jie;XU Caiming;ZHOU Xuehui;LI Xiaojing;ZHENG Siyuan;CHEN Jiamin. Simultaneous Determination of Eleven Elements Released from Plastic Food Contact Materials and Articles by Inductively Coupled Plasma-Mass Spectrometry[J]. Food Science, 2015, 36(8): 236-239. DOI: 10.7506/spkx1002-6630-201508044
Authors:CHEN Minshi  ZHENG Jie  XU Caiming  ZHOU Xuehui  LI Xiaojing  ZHENG Siyuan  CHEN Jiamin
Affiliation:Fujian Key Laboratory Technology Research of Inspection and Quarantine, State Key Laboratory of Safety Testing of Consumer Products,Inspection and Quarantine Technique Center of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350003, China
Abstract:An inductively coupled plasma-mass spectrometry (ICP-MS) method was developed and applied to determine
lead, cadmium, chromium, arsenic, mercury, antimony, zinc, germanium, nickel, selenium and barium released from plastic
food contact materials and articles. Samples were immersed in 4% acetic acid, and incubated for a specific time at a specific
temperature. After being added with gold stabilizer, the immersion solution was filtered through a 0.45 μm microporous
membrane, and then analyzed by ICP-MS. The quantification was performed by internal standard method. Under the
optimum conditions, the calibration curves were linear in the range of 0.1 to 100 μg/L with correlation coefficients (r) above
0.999. The method provided recoveries of 97.5%–106.2% at low, medium and high spiked concentrations with relative
standard deviation (RSD) in the range of 0.72% to 2.76%. The satisfied experimental results indicated that the proposed
method is simple, fast, reproducible, accurate and useful to determine eleven elements.
Keywords:inductively coupled plasma-mass spectrometry (ICP-MS)  element  release  plastic  food contact materials and articles  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《食品科学》浏览原始摘要信息
点击此处可从《食品科学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏