首页 | 本学科首页   官方微博 | 高级检索  
     


Analysis of the steady state characteristics of doubly fedsynchronous machines
Authors:Tamura  J Sasaki  T Ishikawa  S Hasegawa  J
Affiliation:Kitami Inst. of Technol.;
Abstract:A theoretical and experimental analysis of the steady-state characteristics of a doubly fed synchronous machine (DFSM) is presented. The basic equations and the equivalent circuit that represent the steady state of the DFSM are derived. In the experiments, a three-phase symmetrical wound-rotor terminals were connected to the three-phase bus, and the rotor terminals were connected to the slip-frequency source. A DC generator was directly connected to the DFSM as a load. An AC generator driven directly by a DC motor was used as the slip-frequency source. The theoretical results were confirmed. The rotor iron loss remains an important factor, but its effect is shown to be small when slip is small