摘    要:在分析最不利受力情况下钢管径向变形的基础上,结合工程实际,得出钢质外护管最小壁厚、合理壁厚的计算式。计算了外径为273~2020mm的钢质外护管的最小壁厚、合理壁厚。

关 键 词:直埋蒸汽管道  钢质外护管  最小壁厚  合理壁厚

Determination of Wall Thickness of Steel Jacket of Directly Buried Steam Pipeline
ZHOU Dong,GAO Bai-zheng. Determination of Wall Thickness of Steel Jacket of Directly Buried Steam Pipeline[J]. Gas & Heat, 2008, 28(10)
Authors:ZHOU Dong  GAO Bai-zheng
Abstract:Based on analyzing the radial deformation of steel pipe in the most unfavorable load case,the calculation formulas for the minimum and reasonable wall thicknesses of steel jacket are ob- tained with engineering practice.The minimum and reasonable wall thicknesses of steel jacket with exter- nal diameter of 273 to 2 020 mm are calculated.