Oxygen removal with D2-ICR cleanings after oxidation experiment in HT-7 |
| |
Authors: | JS Hu JG Li YP Zhao HT- team |
| |
Affiliation: | Institute of Plasma Physics, Chinese Academy of sciences, P.O. Box 1126, Hefei, Anhui 230031, PR China |
| |
Abstract: | The effectiveness of D2-ICR cleaning with a pressure up to 0.18 Pa was surveyed on hot walls of 400-470 K for oxygen removal after oxidation experiment in the HT-7 superconducting tokamak. The oxygen removal rate in D2-ICR cleaning was about (7-9) × 1021 O-atoms/h, about 5-10 times higher that that He-ICR cleanings before and after the D2-ICR cleaning. In about 130 min He-ICR and D2-ICR cleanings, about 8 × 1021 O-atoms were removed. After the cleanup, a lot of water still retained in HT-7 vessel and 67 disruptive plasmas were required before obtaining normal plasma. In present experiment, the recovered plasmas were easily controlled and much better than previous report in HT-7 oxidation experiments. |
| |
Keywords: | 52 40 Hf |
本文献已被 ScienceDirect 等数据库收录! |
|