首页 | 本学科首页   官方微博 | 高级检索  
     


Development of microphone leak detection technology on Fugen NPP
Authors:S. Shimanskiy   T. Iijima  Y. Naoi
Affiliation:

aJapan Nuclear Cycle Development Institute (JNC), Fugen Nuclear Power Plant 3, Myojin-cho, Tsuruga, Fukui, 914-8510, JAPAN

Abstract:A method of leak detection, based on high-temperature resistant microphones, was originally developed in JNC to detect leakages with flow rates from 1 m3/h to 500m3/h. The development performed on Fugen is focused on detection of a small leakage at an early stage. Specifically, for the inlet feeder pipes the leak rate of 0.2gpm (0.046m3/h) has been chosen as a target detection capability. Evaluation of detection sensitivity was carried out in order to check the capability of the method to satisfy this requirement. The possibility of detecting and locating a small leakage has been demonstrated through the research.
Keywords:Leak detection   leak localization   microphone   acoustic signal processing   Fugen
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏