14 MeV快中子照相准直屏蔽系统的设计与优化
引用本文:王捷,李雅男,李桃生,王永峰. 14 MeV快中子照相准直屏蔽系统的设计与优化[J]. 原子能科学技术, 2019, 53(6): 1105-1111. DOI: 10.7538/yzk.2018.youxian.0527
作者姓名:王捷  李雅男  李桃生  王永峰
作者单位:1.中国科学院 核能安全技术研究所,中子输运理论与辐射安全重点实验室,安徽 合肥230031;2.中国科学技术大学,安徽 合肥230026
摘    要:基于强流氘氚中子源科学装置HINEG设计了一套快中子照相准直屏蔽系统。采用中子输运设计与安全评价软件系统SuperMC和ENDF/B-Ⅶ.0数据库计算了准直中子束的中子能谱及注量率、γ射线能谱及注量率、直射中子注量率与γ射线注量率比值(φdγ)、直射与散射中子注量率比值(φds)、准直束中子注量率的不均匀度等特性参数,并采用MCNP5程序进行了对比验证。研究了准直屏蔽系统的内衬材料、尺寸等对特性参数的影响规律,并通过优化获取了最优设计方案。计算结果显示,在同等计算条件下,SuperMC计算结果与MCNP计算结果相对偏差小于1%,准直屏蔽系统的φdγ为50.1,φds为5.7,在Φ30 cm视野范围内的中子注量率为4.80×107 cm-2•s-1,其中直射中子注量率为4.09×107 cm-2•s-1,中子注量率不均匀度为5.8%,满足快中子照相对准直束特性参数的要求。

关 键 词:快中子照相   准直屏蔽系统   中子源   SuperMC   MCNP

Design and Optimization of Shielding Collimator System for 14 MeV Fast Neutron Radiography
WANG Jie,LI Yanan,LI Taosheng,WANG Yongfeng. Design and Optimization of Shielding Collimator System for 14 MeV Fast Neutron Radiography[J]. Atomic Energy Science and Technology, 2019, 53(6): 1105-1111. DOI: 10.7538/yzk.2018.youxian.0527
Authors:WANG Jie  LI Yanan  LI Taosheng  WANG Yongfeng
Affiliation:1.Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei 230031, China;2.University of Science and Technology of China, Hefei 230026, China
Abstract:A shielding collimator system of fast neutron radiography was designed based on High Intensity D-T Fusion Neutron Generator. The beam characteristic parameters of the shielding collimator system, including neutron energy spectrum and fluence rate, γ-ray energy spectrum and fluence rate, direct neutron fluence rate and gamma fluence rate ratio (φdγ), direct neutron fluence rate and scattered neutron fluence rate ratio (φds) and neutron fluence rate uniformity were calculated by SuperMC code coupled with ENDF/B-Ⅶ.0 library, and the MCNP5 code was used to verify the results. The lining material and its thickness of the shielding collimator system were studied aiming to acquire the optimal design. The results show that the deviation between the calculated results of SuperMC and MCNP is less than 1% under the same condition, and theφdγds, the total neutron fluence rate withinΦ30 cm,φd and its uniformity are about 50.1, 57,4.80×107 cm-2•s-1,4.09×107 cm-2•s-1 and 5.8% respectively, which can meet the need of fast neutron radiography facility.
Keywords:fast neutron radiography  shielding collimator system  neutron source  SuperMC  MCNP  