Hp(0.07) photon irradiations at Seibersdorf for the EURADOS extremity dosemeter intercomparison 2009 |
| |
Authors: | Stadtmann H Hranitzky C |
| |
Affiliation: | Seibersdorf Labor GmbH, Radiation Safety and Applications, Dosimetry, 2444 Seibersdorf, Austria. hannes.stadtmann@seibersdorf-laboratories.at |
| |
Abstract: | In August 2009, almost 1000 passive extremity dosemeters were irradiated at the Dosimetry Laboratory Seibersdorf as part of the EURADOS intercomparison IC2009. Forty-four European individual monitoring services participated, with a total of 59 dosimetry systems (46 finger ring, 4 finger tip and 9 wrist/ankle dosemeter systems). Additionally, finger-ring dosemeters from the Dosimetry Service Seibersdorf were irradiated in a non-competitive manner. Dosemeter irradiations on rod and pillar phantoms in four photon-radiation fields complying with the ISO standard 4037 were performed with personal dose equivalent values (H(p)(0.07)) ranging from 4 to 480 mSv. Traceability was established by using an air-kerma-calibrated monitor ionisation chamber together with the X-ray facility as well as a calibrated (137)Cs gamma radiation field with a collimated beam geometry. The ISO-tabulated conversion coefficients from air kerma free-in-air to H(p)(0.07) were applied, resulting in the main contribution to the expanded measurement uncertainties. |
| |