Removal of ciprofloxacin from aqueous solution by a continuous flow electro-coagulation process |
| |
Authors: | Jalal?Basiri?Parsa Taher?Mehdi?Panah Email author" target="_blank">Farideh?Nabizadeh?ChianehEmail author |
| |
Affiliation: | 1.Department of Applied Chemistry, Faculty of chemistry,University of Bu-Ali Sina,Hamadan,Iran |
| |
Abstract: | This study deals with the performance and modeling of the electro-coagulation process for ciprofloxacin (CIP) removal by using aluminum electrode as anode in a continuous electrochemical reactor. The initial pH, temperature, current density, time and flow rate were selected as independent variables in response surface methodology (RSM) involving a five-level central composite design (CCD), while CIP removal efficiency was considered as the response function. The result of optimization showed that the maximum amount of CIP removal efficiency (88%) presented at the optimal condition of pH=5.6, t=100min, T=25.5 °C, I=5.6mA/cm2 and V=25.9 mL/min. In addition, the mineralization of the CIP was investigated by chemical oxygen demand (COD) and total organic carbon (TOC) measurements that showed 77% COD removal and 49%TOC removal. |
| |
Keywords: | |