首页 | 本学科首页   官方微博 | 高级检索  
     


Accuracy of Safety Valve Two‐Phase Mass Flow Capacity Sizing
Authors:H. Derlien  L. Friedel
Abstract:The method specified in ISO/CD 4126–10 exhibits the highest accuracy compared to other models used in industry and academia. At the same time it allows for an oversizing of the necessary relief area under all test conditions. The average or statistical reproductive accuracy is characterized by an unacceptable logarithmic scatter of about 80 %.
Keywords:Safety techniques  Steam  Two‐Phase flow  Water