摘    要:气密性、绝缘性和六氟化硫气体微水含量,是直接影响六氟化硫气体绝缘开关设备性能和质量的关键技术指标,通过对影响上述技术指标的主要因素分析,列举了产品在装配作业过程中应注意的关键点,提出了解决的方法和有效控制手段,以确保和提高产品质量,使产品达到和超过国家标准及设计要求。

关 键 词:六氟化硫气体绝缘开关设备  气密性  绝缘性  微水含量

Assembly Quality Control on Sulphur Hexafluoride Insulated Switchgear
Authors:NING Mao-liang  ZHOU Qing-qing
Affiliation:Zhejiang Switchgear Factory Co.;Ltd;Quzhou 324000;China
Abstract:Air-tightness, insulativity and sulphur hexafluoride micro-moisture are the key technical specifications directly impacting on sulphur hexafluoride insulated switchgear performance and quality. Via analysis on main factors mentioned above, the considerable key points in product assembling operation process were enumerated, solutions and effective control means presented, so as to ensure and raise product quality, making products reach and surpass the national standard and design requirements.