摘    要:在PMU最优配置问题的研究过程中,引入了元件权重的概念,来区分不同设备对可观性要求的程度使得OPP求解算法更加灵活,可以考虑更多的因素;结合了发电机同调性的影响,此方法针对电力系统的特点,从而更加有效;把传统的逐点法进行了改进,并根据穷举法与改进逐点法的各自特点,把两者相结合,成为一种实用算法。对以上布点原则和算法在IEEE-39上进行了测试,取得了较好的效果。

关 键 词:电力系统  PMU  OPP问题  相量测量单元  改进逐点法

Optimal PMU Configuration in Power System
QIAO Xiao-yan,QIAO Kun,MENG Xin and SHE Na. Optimal PMU Configuration in Power System[J]. Advance of Power System & Hydroelectric Engineering, 2010, 26(10): 26-29
Authors:QIAO Xiao-yan  QIAO Kun  MENG Xin  SHE Na
Affiliation:School of Hydropower Engineering,Hebei Engineering University, Handan 056038, Hebei Province, China;Yuncheng Electric Power Supply Company , Yuncheng 044000, Shanxi Province, China;School of Hydropower Engineering,Hebei Engineering University, Handan 056038, Hebei Province, China;School of Hydropower Engineering,Hebei Engineering University, Handan 056038, Hebei Province, China
Abstract:The current study introduces the concept of the component (including bus and line) weight, so as to distinguish between the different equipment requirements of the observability degree; and takes into consideration of the impact of the generator coherence, since changes of one node's observability affect the rest of nodes among coherent generator groups; and improves the traditional point to point method, and forms a practical method through combining Exhaustion Method and point to point method together. Finally, the principles and algorithms above are tested in the IEEE-39 system, and positive results are achieved.
Keywords:power system   PMU   OPP   phasor measurement unit   improved point to point method