首页 | 本学科首页   官方微博 | 高级检索  
     

基于VMD的建筑结构模态参数识别
引用本文:孙猛猛,郅伦海.基于VMD的建筑结构模态参数识别[J].振动与冲击,2020,39(1):175-183.
作者姓名:孙猛猛  郅伦海
作者单位:1. 武汉理工大学 土木工程与建筑学院,武汉430070;
2. 合肥工业大学土木与水利工程学院,合肥230009;
3. 湖南科技大学 土木工程学院,湘潭411201
基金项目:国家自然科学基金(51478371;51978230);中央高校基本科研业务费专项资金资助(2017II30GX);湖南科技大学结构抗风与振动控制湖南省重点实验室开放基金资助项目
摘    要:在建筑结构的健康监测、控制和状态评估中经常遇到的一个关键性问题是如何根据实测响应信号准确估计结构阻尼比及自振频率等模态参数。基于变分模态分解(VMD)提出一种新的结构模态参数识别方法。该方法首先对实测振动信号进行VMD分解,获得单模态信号,然后采用自然环境激励技术(NEXT)得到单模态信号的自由衰减响应,最后利用直接插值法(DI)和曲线拟合获得结构的自振频率和阻尼比。通过三层框架结构的数值模拟验证了该方法的准确性及可靠性。利用该技术对台风“达维”作用下广州中信广场的实测加速度数据进行分析,并将估计的结构模态参数和其他识别方法的分析结果进行对比,进一步验证了该方法的准确性和有效性。

关 键 词:模态参数识别  变分模态分解  直接插值法  阻尼比  自振频率  建筑结构

Modal parametric identification of building structures based on VMD
SUN Mengmeng,ZHI Lunhai.Modal parametric identification of building structures based on VMD[J].Journal of Vibration and Shock,2020,39(1):175-183.
Authors:SUN Mengmeng  ZHI Lunhai
Affiliation:1. School of Civil Engineering and Architecture, Wuhan University of Technology, Wuhan 430070, China; 2. School of Civil and Hydraulic Engineering, Hefei University of Technology, Hefei 230009, China; 3. School of Civil Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
Abstract:A key issue in health monitoring, control and condition assessment of building structures is correctly estimating their modal parameters including structural damping ratios, natural frequencies, etc. based on measured response signals. Here, a new structural modal parametric identification approach was proposed based on variational mode decomposition (VMD).With the proposed method, a measured vibration signal was decomposed using VMD to obtain various modal signals. Then, free decay response of each mode was obtained using NEXT technique. Finally, the direct interpolation (DI) method and the curve fitting one were used to estimate various modes’ natural frequencies and damping ratios. The numerical simulation for a 3-story frame structure was employed to verify the correctness and reliability of the proposed method. The measured acceleration response data of CITIC Plaza in Guangzhou under Typhoon Damrey were analyzed using the proposed approach. The estimated structural modal parameters were compared with those obtained using other recognition methods to further verify the correctness and reliability of the proposed method.
Keywords:modal parameter identification                                                      variational mode decomposition (VMD)                                                      direct interpolation                                                      damping ratio                                                      natural frequencies                                                      building structure
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《振动与冲击》浏览原始摘要信息
点击此处可从《振动与冲击》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号