首页 | 本学科首页   官方微博 | 高级检索  
     

低共模电压三相准单级逆变器空间矢量调制策略
引用本文:张犁,马天睿,张涛,王江峰,孙凯.低共模电压三相准单级逆变器空间矢量调制策略[J].电力自动化设备,2022,42(2):134-140.
作者姓名:张犁  马天睿  张涛  王江峰  孙凯
作者单位:河海大学 能源与电气学院,江苏 南京 211100;清华大学 电机工程与应用电子技术系,北京 100084
基金项目:国家自然科学基金资助项目(51677054);江苏省六大人才高峰创新团队资助计划(2019-TD-XNY-001)
摘    要:由于部分光伏功率可单级传输馈入电网,三相准单级逆变器的变换效率高于传统三相两级式逆变器,但共模电压幅值和频率变化量较高.提出一种适用于三相准单级逆变器的低共模电压空间矢量调制(LCSVPWM)策略,通过舍弃部分小矢量和替换零矢量,降低了共模电压幅值和频率的变化量.此外,通过理论计算,比较了三相准单级逆变器分别采用传统空...

关 键 词:逆变器  共模电压  空间矢量调制策略  光伏  效率

SVPWM scheme for low common-mode voltage of three-phase quasi-single-stage inverter
ZHANG Li,MA Tianrui,ZHANG Tao,WANG Jiangfeng,SUN Kai.SVPWM scheme for low common-mode voltage of three-phase quasi-single-stage inverter[J].Electric Power Automation Equipment,2022,42(2):134-140.
Authors:ZHANG Li  MA Tianrui  ZHANG Tao  WANG Jiangfeng  SUN Kai
Affiliation:College of Energy and Electrical Engineering, Hohai University, Nanjing 211100, China;Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
Abstract:Since part of the photovoltaic power can be fed to the grid with single-stage power conversion, three-phase quasi-single-stage inverter has higher efficiency than that of conventional three-phase two-stage inverter. However, it still has the issue of high variation of amplitude and frequency of common-mode voltage. A LCSVPWM(Low Common-mode voltage Space Vector Pulse Width Modulation) scheme is proposed to reduce the variation of amplitude and frequency of common-mode voltage by omitting part of small voltage vectors and replacing zero voltage vectors. In addition, by calculating theoretically, the power losses of switching devices in three cases are compared, including the three-phase quasi-single-stage inverter adopting the CSVPWM(Conventional Space Vector Pulse Width Modulation) scheme and LCSVPWM scheme, and the three-phase two-stage inverter adopting seven-segment SVPWM scheme. A prototype of a 3 kW three-phase quasi-single-stage inverter is built. Experimental results show that when the input voltage is low, the variation of amplitude and frequency of common-mode voltage of inverter adopting LCSVPWM scheme is lower than that adopting CSVPWM scheme. In addition, the efficiency of the three-phase quasi-single-stage inverter adopting LCSVPWM scheme is slightly lower than that adopting CSVPWM scheme, but higher than that of the three-phase two-stage inverter. Thus, LCSVPWM scheme has advantages in improving both efficiency and common-mode performance.
Keywords:electric inverters  common-mode voltage  space vector pulse width modulation  photovoltaic  efficiency
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《电力自动化设备》浏览原始摘要信息
点击此处可从《电力自动化设备》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号