首页 | 本学科首页   官方微博 | 高级检索  
     


Simultaneous measurement of gas hold-up and mass transfer coefficient by tracer dynamic technique in “Emulsair” reactor with an emulsion-venturi distributor
Authors:B. Gourich  M. Belhaj Soulami  M. Ziyad
Affiliation:a Laboratoire de Génie des Procédés, Ecole Supérieure de Technologie de Casablanca, B.P. 8012, Oasis Casablanca, Morocco
b Laboratoire d,Ingénierie des Procédés et Environnement, (LIPE), ENIM BP 753 Agdal Rabat, Morocco
c Laboratoire de Génie des Procédés, ESSTIB, Université de Nancy I, B.P. 239, 54506 Vandoeuvre Cedex, France
d Département de Chimie, Faculté des sciences, Université Mohammed V, Avenue Ibn Battouta, B.P. 1014, Rabat, Morocco
Abstract:Hydrodynamics and gas-liquid mass transfer have been investigated in an “Emulsair” reactor with cocurrent downflow of gas and liquid. This consists of a cylindrical tank with conical bottom topped by an emulsion-venturi as the gas-liquid distributor in which the gas is self-aspired by action of the kinetic energy of the liquid recirculation. An original tracer dynamic technique using the CO2-N2/water system that enables the simultaneous measurement of overall gas hold-up and overall volumetric mass transfer coefficient has been developed and validated using conventional techniques, such as volume expansion for gas hold-up and dynamic oxygenation for mass transfer. It has been shown that gas hold-up and KLaL can be deduced from the moments of experimental response curves using a CO2 pulse in the gas feed. Experimental results have proved that hydrodynamics and mass transfer in the Emulsair reactor are strongly influenced by the flow regime in the divergent. Two different regimes have been observed depending on the liquid recirculation flow rate: annular and homogeneous bubbling flows. In both regimes, self-aspired gas flow rate, gas hold-up and KLaL have been reported to increase with the liquid flow rate. The operation effectiveness, estimated from the gas-to-liquid flow rate ratio, has been shown to pass through a maximum around 0.59 as a function of liquid recirculation. A comparison with the literature proved that this maximum is higher than those observed for other kinds of gas-liquid reactors equipped with a venturi. Correlations for mass transfer estimation have been derived and are in agreement with the literature.
Keywords:Emulsion-venturi   Gas hold-up   Mass transfer   Tracer dynamic method
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号