首页 | 本学科首页   官方微博 | 高级检索  
     


Leak detection in pipe using transient flow and genetic algorithm
Authors:Young-joon Kim  Koji Miyazaki  Hiroshi Tsukamoto
Affiliation:(1) Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu, Kitakyushu, Japan
Abstract:An inverse transient method with genetic algorithm (GA) was applied to leak detection in pipeline. Transient flow caused by valve operation was calculated using the characteristics method. The location and discharge of leak were determined so that the difference of the calculated pressure may be minimized from the reference pressure calculated under a given leak condition. Calculations were done for the leak at one and two locations in pipeline. Furthermore, the effect of noise in pressure data was discussed, and the leak locations and leak discharges can be predicted precisely even in the case of noisy data. This paper was presented at the 9th Asian International Conference on Fluid Machinery (AICFM9), Jeju Korea, October 16–19, 2007.
Keywords:Leak detection  Transient flow  Genetic algorithm  Characteristic method