首页 | 本学科首页   官方微博 | 高级检索  
     


Estimation of the number of trays for natural gas triethylene glycol dehydration column
Authors:Branislav M Ja?imovi?Srbislav B Geni?  Dimitrije R Djordjevi?Nikola J Budimir  Marko S Jari?
Affiliation:a Faculty of Mechanical Engineering, University of Belgrade, Kraljice Marije 16, 11000 Belgrade, Serbia
b Termoliv, Knjaza Miloša bb, 31210 Pozega, Serbia
Abstract:The paper deals with the tray-to-tray method for determining the required number of trays in columns with intensive entrainment of liquid when the operating line of the “dry working regime” is not straight and with a small concentration of diffusing component in gas. Presented calculations show that the number of transfer units for gas and liquid should be calculated using the AIChE method accompanied with longitudinal mixing according to Gilbert properly transformed for case of diffusion through stagnant film. The suggested method can be applied for TEG dehydration absorbers-columns for dehydration of natural gas using triethylene glycol with system factor SF = 0.5.
Keywords:Computation  Diffusion  Unit operations  Absorption  Dehydration  Natural gas
本文献已被 ScienceDirect 等数据库收录!