首页 | 本学科首页   官方微博 | 高级检索  
     

300MW燃煤机组上主燃料跳闸停炉不停机的实践
引用本文:侯昭毅.300MW燃煤机组上主燃料跳闸停炉不停机的实践[J].发电设备,2011,25(3):177-179.
作者姓名:侯昭毅
作者单位:国电菏泽发电厂,菏泽,274032
摘    要:结合国电菏泽发电厂300 Mw燃煤机组锅炉主燃料跳闸后因恢复时间长而产生的问题,提出用主蒸汽低过热度保护代替锅炉MFT联跳汽轮机的保护逻辑.介绍了锅炉MFT后吹扫点火程序的优化和汽轮机低汽温条件下保护的技术措施,并成功地实现了停炉不停机,为同类机组锅炉MFT后的恢复方式提供参考.

关 键 词:燃煤机组  锅炉主燃料跳闸  停炉不停机

Practice of the Boiler Halt Without Stopping Power Unit after Main Fuel Trip on 300 MW Fossil Fire Unit
HOU Zhao-yi.Practice of the Boiler Halt Without Stopping Power Unit after Main Fuel Trip on 300 MW Fossil Fire Unit[J].Power Equipment,2011,25(3):177-179.
Authors:HOU Zhao-yi
Affiliation:HOU Zhao-yi (Heze Power Plant,China Guodian Corporation,Heze 274032,China)
Abstract:The scheme of low overheat protection of main steam instead of the protection logic of the boiler tripping of turbine after main fuel trip(MFT)has been put forward in the paper combined with the problem of long time recovery on 300 MW fossil-fired power unit with boiler MFT in Guodian Heze Power Plant.The optimization of igniting program after MFT and the protection measures in the condition of low temperature in turbine have been described.The practice of boiler halt without stopping power unit was successfully realized so as to provide a reference on the recovery of the power unit of same type after MFT.
Keywords:fossil-fired unit  boiler main fuel trip  boiler halt without stopping power unit
本文献已被 CNKI 万方数据 等数据库收录!