首页 | 本学科首页   官方微博 | 高级检索  
     

贵阳电厂9号机低压胀差大的原因分析及处理
引用本文:李浪艇,文贤馗.贵阳电厂9号机低压胀差大的原因分析及处理[J].发电设备,2002(4):8-10,13.
作者姓名:李浪艇  文贤馗
作者单位:1. 贵阳发电厂,贵州,贵阳,550002
2. 贵州电力试验研究院,贵州,贵阳,550002
摘    要:从产生胀差的机理来分析贵阳电厂 9号机低压胀差大的原因 ,判断出滑销系统卡涩导致中压缸热胀偏小 ,中压缸胀差大 ,从而引起低压胀差接近报警值 ,在机组大修中将前、中轴承箱及高压下缸吊出检修 ,提出在运行及检修中应注意的事项。图 2表 2

关 键 词:汽轮机  低压缸  胀差
文章编号:1671-086X(2002)04-0008-03

Excessive L.P. Cylinder Differential Expansion of Guiyang Power Plant's Set No.9——Causes and Coping Measures
LI Lang ting ,WEN Xian kui.Excessive L.P. Cylinder Differential Expansion of Guiyang Power Plant''''s Set No.9——Causes and Coping Measures[J].Power Equipment,2002(4):8-10,13.
Authors:LI Lang ting  WEN Xian kui
Affiliation:LI Lang ting 1,WEN Xian kui 2
Abstract:Judging by the mechanism of differential expansion, it is reasoned that insufficient thermal expansion and excessive differential expansion of the L.P. cylinder of Guiyang Power Plant's No.9 turbine, wich are due to seizure occurring in the gliding key system, has caused the L.P. differential expansion to become so excessive as to trigger off alarm. Thus the middle bearing pedestal and the lower H.P. turbine casing was removed for checking during the set's general overhaul and a list of points to be observed during operation and overhaul set up. Figs 2, table 1 and refs 2.
Keywords:steam turbine  L  P  cylinder  differential expansion  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏