摘 要: | 近年来我国发生了多起高层建筑火灾。高层建筑因其致火因素多、建筑高度大,一旦发生火灾蔓延快,疏散、扑救都比较困难,为此应立足于"自救"。通过实例介绍了高层建筑消火栓给水系统设计的一般方法,可为工程设计人员提供参考。
|
关 键 词: | 高层建筑 消防给水 消火栓 减压孔板 |
Design and Calculation for Water Supply System of Fire Hydrant in High-rise Building |
| |
Abstract: | In recent years,a number of fires in high-rise building have occurred in China.These fires are more difficult to be fought because of the multi-factors of fires,building height,and fire quickly spread,and so on.So it should be based on "self-saving".Here through examples,the design about the water supply system of fire hydrant is introduced in order to provide references for designers. |
| |
Keywords: | high-rise building fire water supply fire hydrant pressure reducing orifice |