首页 | 本学科首页   官方微博 | 高级检索  
     


Thermal performance and embodied energy analysis of a passive house – Case study of vault roof mud-house in India
Authors:Arvind Chel  GN Tiwari
Affiliation:Center for Energy Studies (CES), Indian Institute of Technology Delhi, Block V, Hauz Khas, New Delhi 110 016, India
Abstract:This paper investigates thermal performance of an existing eco-friendly and low embodied energy vault roof passive house (or mud-house) located at Solar Energy Park of IIT Delhi, New Delhi (India). Based on embodied energy analysis, the energy payback time for the mud-house was determined as 18 years. The embodied energy per unit floor area of R.C.C. building (3702.3 MJ/m2) is quiet high as compared to the mud-house (2298.8 MJ/m2). The mud-house has three rooms with inverted U-shape roof and remaining three rooms with dome shape roof. A thermal model of the house consisting of six interconnected rooms was developed based on energy balance equations which were solved by using fourth order Runge Kutta numerical method. The predicted six room air temperatures were found in good agreement with the experimental observed data on hourly basis in each month for one year. The annual heating and cooling energy saving potential of the mud-house was determined as 1481 kW h/year and 1813 kW h/year respectively for New Delhi composite climate. The total mitigation of CO2 emissions due to both heating and cooling energy saving potential was determined as 5.2 metric tons/year. The annual carbon credit potential of mud-house was determined as € 52/year. Similar results were obtained for the different climatic locations in India.
Keywords:Vault roof  Embodied energy  Energy saving  Mitigation of CO2  Carbon credit
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号