摘    要:对邹县发电厂1000t/h锅炉水冷壁及刚性梁低周振动进行了现场调查研究,从设计安装,设备系统和运行操作3方面详细分析引起水冷壁及刚性梁低周振动的原因。经采取针对性的改进措施,取得了较好效果。

关 键 词:水冷壁 刚性梁 低周振动 锅炉
修稿时间:2000-02-23

Causes Analysis and Solutions of Low Cycle Vibration of Water Wall and Rigid Beamson 1 000 t/h Boiler
FU FENG. Causes Analysis and Solutions of Low Cycle Vibration of Water Wall and Rigid Beamson 1 000 t/h Boiler[J]. Electric Power, 2000, 33(8): 15-17
Authors:FU FENG
Abstract:The low cycle vibration problems of water wall and rigid beams existing on 1000 t/h boilers of Shandong Zouxian Power Plant were investigated and studied. Thispaper describes in detail the impacts of design, erection, operation and system ofboiler and analyzes the causes leading to low cycle vibration of water wall and rigidbeams. Through improvement, the existing problems have been satisfactorily solved.
Keywords:boiler water wall  rigid beam  low cycle vibration