摘    要:上海外高桥电厂 90 0MW机组凝汽器的结构特点是 :凝汽器与低压缸为刚性联接 ;凝汽器采用弹簧支撑 ,且可多向膨胀 ;设置抽空气母管 ,使空冷区的空气直接、迅速抽出 ;采用阴极保护和衬胶进行防腐。建议 :为保证支撑弹簧受力均匀 ,安装时可在弹簧座上设千斤顶 ,测间距 ,配垫片 ;凝汽器顶部应设计成“T”型。

关 键 词:900MW机组  凝汽器  结构特点  安装方法
文章编号:1000-7229(2003)03-0008-02
收稿时间:2010-01-25
修稿时间:2002-09-18

Structural Characters of 900 MW Unit Condenser and Its Installation Method
Chen Shuilong. Structural Characters of 900 MW Unit Condenser and Its Installation Method[J]. Electric Power Construction, 2003, 24(3): 8-0
Authors:Chen Shuilong
Abstract:The structural characters of condenser for 900 MW unit in Shanghai Waigaoqiao Power Plant are as follows: stiff linkage of condenser with LP casing, spring support for condenser with expansion in multi-directions, installation of air extraction mains for direct and quick extraction of air from air cooling area, cathode protection and rubber lining for anti-corrosion. The comments are that a jack can be provided on the spring stand to ensure the uniform supporting force applied on the springs with measurement of distance and installation of spacers; while the top of condenser should be designed with"T"shape.