首页 | 本学科首页   官方微博 | 高级检索  
     

310t/h循环流化床锅炉一次风机改造
引用本文:窦晓春.310t/h循环流化床锅炉一次风机改造[J].发电设备,2011,25(6):440-443.
作者姓名:窦晓春
作者单位:中国石油化工股份有限公司北京燕山分公司,北京,102500
摘    要:介绍了全烧石油焦310t/h循环流化床锅炉一次风机选型参数的确定方法,讨论了在调试和初期运行阶段中风机出现的问题和对锅炉运行造成的影响,分析了原因,提出了改造方案,并对改造后的效果进行了评价。

关 键 词:循环流化床锅炉  一次风机  风压  风量  裕量

Retrofit on the Primary Air Fan of a 310t/h CFB Boiler
DOU Xiao-chun.Retrofit on the Primary Air Fan of a 310t/h CFB Boiler[J].Power Equipment,2011,25(6):440-443.
Authors:DOU Xiao-chun
Affiliation:DOU Xiao-chun Beijing Yanshan Petrochemical Co.,Ltd.,SINOPEC,Beijing 102500,China
Abstract:The selection of parameters of primary air fans for 310t/h CFB boiler has been introduced.The reason of the problem occurring in the fan against CFB boiler during the commissioning and primary operation has been analyzed and the retrofit scheme has been put forward.Finally an evaluation on the retrofit effect has been carried out.
Keywords:CFB boiler  primary air fan  air pressure  air volume  allowance  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号