首页 | 本学科首页   官方微博 | 高级检索  
     

330MW机组电动给水泵效率低原因分析及处理
引用本文:丁海丽.330MW机组电动给水泵效率低原因分析及处理[J].宁夏电力,2014(1):62-65.
作者姓名:丁海丽
作者单位:宁夏电力能源科技有限公司,宁夏银川750011
摘    要:针对330 MW发电机组电动给水泵效率低的问题,通过进行效率试验,并对测试结果综合分析,找出电动给水泵效率低的原因,提出了改进方案。改造结果表明:单台电动给水泵效率提高约1.48%,每年可节约厂用电约3.02 GW·h,节能效果显著。

关 键 词:330  MW发电机组  电动给水泵  效率  耗电率

Cause analysis and treatment of feedwater pump motor inefficiency for 330 MW power unit
DING Haili.Cause analysis and treatment of feedwater pump motor inefficiency for 330 MW power unit[J].Ningxia Electric Power,2014(1):62-65.
Authors:DING Haili
Affiliation:DING Haili (Ningxia Power Energy Science & Technology Co., Ltd., Yinchuan Ningxia 750011, China)
Abstract:Aiming at the problems of feedwater pump motor inefficiency in 330 MW power unit, by making efficiency test, comprehensively analyzes the testing results, finds out the reasons of feed- water pump motor inefficiency, puts forward improvement schemes. The improvement result shows that the efficiency of single feedwater pump motor is increased 1.48%, saves electric auxiliary system power about 3.02 (GW.h)/y, the energy saving effect is prominent.
Keywords:330 MW power unit  feedwater pump motor  efficiency  electricity consumption rate