首页 | 本学科首页   官方微博 | 高级检索  
     

1 036 MW机组汽轮机冷端运行优化及循泵双速节能改造的试验研究
引用本文:卢怀钿,钟少伟. 1 036 MW机组汽轮机冷端运行优化及循泵双速节能改造的试验研究[J]. 电力建设, 2011, 32(7): 109-112. DOI: 10.3969/j.issn.1000-7229.2011.07.025
作者姓名:卢怀钿  钟少伟
作者单位:华能海门电厂,广东省汕头市,515132
摘    要:对华能海门电厂2台1 036 MW机组冷端系统在循环水泵双速改造前后进行了运行优化试验,根据试验数据拟合出汽轮机背压和功率微增曲线及汽轮机功率修正计算公式,并计算出了凝汽器变工况特性;采用综合煤价和电价比较法得出循环水泵双速改造前后的推荐运行方式。实践证明循环水泵双速改造后能达到进一步节能的目的,使电厂获得了最大的经济效益。

关 键 词:凝汽器  冷端优化  循环水泵  双速控制  节能降耗  
收稿时间:2010-11-12

Experimental Research on Double Speed Energy Efficiency Innovation of Water Circulation Pump and Operation Optimization of Cold End System for 1 036 MW Steam Turbine Units
LU Huaitian,ZHONG Shaowei. Experimental Research on Double Speed Energy Efficiency Innovation of Water Circulation Pump and Operation Optimization of Cold End System for 1 036 MW Steam Turbine Units[J]. Electric Power Construction, 2011, 32(7): 109-112. DOI: 10.3969/j.issn.1000-7229.2011.07.025
Authors:LU Huaitian  ZHONG Shaowei
Affiliation:(Huaneng Haimen Power Plant,Shantou 515132,Guangdong Province,China)
Abstract:The operation optimization tests of cold end system are conducted by double speed operation innovation of water circulation pump in two 1 036 MW steam turbine units of Huaneng Haimen power plant.According to the test data,the slight increasing curves of exhaust steam pressure and power are fitted,the correction formula of power is obtained,and the characteristics at variable operating conditions of condenser are calculated.Combined with the integrated coal and electrovalence comparison method,the operation mode for water circulation pump by double speed operation innovation is recommended.It is proved that the double speed operation of water circulation pump can reach the goal of energy saving and obtain the maximum economic benefits for the power plant.
Keywords:condenser  cold end optimization  water circulation pump  double speed control  energy saving
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《电力建设》浏览原始摘要信息
点击此处可从《电力建设》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号