首页 | 本学科首页   官方微博 | 高级检索  
     

Effect of CaCl_2 and NaHCO_3 in Physiological Saline Solution on the Corrosion Behavior of an As-Extruded Mg–Zn–Y–Nd alloy
引用本文:Baojie Wang,Daokui Xu,Tianyu Zhao,Liyuan Sheng. Effect of CaCl_2 and NaHCO_3 in Physiological Saline Solution on the Corrosion Behavior of an As-Extruded Mg–Zn–Y–Nd alloy[J]. 金属学报(英文版), 2021, 34(2): 239-247
作者姓名:Baojie Wang  Daokui Xu  Tianyu Zhao  Liyuan Sheng
作者单位:School of Environmental and Chemical Engineering,Shenyang Ligong University, Shenyang 110159, China;Shenzhen Institute, Shenzhen Key Lab Human Tissue Regenerate and Repair, Peking University, Shenzhen 518057,China;CAS Key Laboratory of Nuclear Materials and Safety Assessment, Institute of Metal Research, Chinese Academy of Sciences, 62 Wencui Road, Shenyang 110016, China;School of Environmental and Chemical Engineering,Shenyang Ligong University, Shenyang 110159, China;Shenzhen Institute, Shenzhen Key Lab Human Tissue Regenerate and Repair, Peking University, Shenzhen 518057,China
摘    要:In this study, the corrosion behaviors of an as-extruded Mg–4%Zn–2%Y–1.8%Nd(in wt.%) alloy in different physiological saline solutions were investigated and compared. The results indicated that the alloy in the 9 g/L NaCl had the higher corrosion resistance than that containing with CaCl_2 and NaHCO_3. Moreover, it demonstrated that the corrosion behaviors of the alloy in two types of solutions were all dependent on the pre-immersion time. In the 9 g/L NaCl solution, the corrosion current densities of the alloy decreased firstly with the pre-immersion time being 4 h and then increased with the pre-immersion time prolonging from 4 to 48 h. However, in the 9 g/L NaCl solution containing with CaCl_2 and NaHCO_3, the corrosion current density of the alloy exhibited the adverse trend with the prolonging the pre-immersion time. Failure analysis demonstrated that the changes of corrosion resistance in two solutions were mainly dominated by the constituents formed in surface films.


Effect of CaCl2 and NaHCO3 in Physiological Saline Solution on the Corrosion Behavior of an As-Extruded Mg-Zn-Y-Nd alloy
Baojie Wang,Daokui Xu,Tianyu Zhao,Liyuan Sheng. Effect of CaCl2 and NaHCO3 in Physiological Saline Solution on the Corrosion Behavior of an As-Extruded Mg-Zn-Y-Nd alloy[J]. Acta Metallurgica Sinica(English Letters), 2021, 34(2): 239-247
Authors:Baojie Wang  Daokui Xu  Tianyu Zhao  Liyuan Sheng
Abstract:In this study,the corrosion behaviors of an as-extruded Mg--4%Zn-2%Y-1.8%Nd (in wt.%) alloy in different physiological saline solutions were investigated and compared.The results indicated that the alloy in the 9 g/L NaC1 had the higher corrosion resistance than that containing with CaC12 and NaHCO3.Moreover,it demonstrated that the corrosion behaviors of the alloy in two types of solutions were all dependent on the pre-immersion time.In the 9 g/L NaC1 solution,the corrosion current densities of the alloy decreased firstly with the pre-immersion time being < 4 h and then increased with the pre-immersion time prolonging from 4 to 48 h.However,in the 9 g/L NaC1 solution containing with CaCl2 and NaHCO3,the corrosion current density of the alloy exhibited the adverse trend with the prolonging the pre-immersion time.Failure analysis demonstrated that the changes of corrosion resistance in two solutions were mainly dominated by the constituents formed in surface films.
Keywords:Magnesium alloy  Biomaterial  Corrosion  Simulated body fluids  Pre-immersion
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号