A comprehensive technique for measuring the three-dimensional positioning accuracy of a rotating object |
| |
Authors: | Dr E. S. Lee H. G. Wi |
| |
Affiliation: | (1) Automation Division, RIST, Pohang, Korea;(2) RIST, PO box 135, 790-330 Pohang, South Korea |
| |
Abstract: | A method for measuring the accuracy of rotating objects was studied. Rotating axis errors are significant; such as the spindle error of a machine tool which results in increased surface roughness of machined work pieces. Three capacitance-type displacement sensors were used to measure the position of a rotating master ball. The sensors were mounted at the three orthogonal points on the spindle axis. The measurement data were analysed for rotating spindle accuracy, not only for the average roundness error but also for the spindle volumetric positional error during rotation. This method is simple and economical for industrial field use for regular inspection of spindles using portable equipment. The time taken for measurement and analysis using this method is only about two hours. This method can also measure microscopic amplitudes in 3-D directions of vibrating objects. |
| |
Keywords: | Capacitance sensor Rotating spindle accuracy Volumetric positioning error |
本文献已被 SpringerLink 等数据库收录! |
|