摘    要:This paper reports a field testing of full scale PCC (Pulverized Coal Combustion) boiler study into the influence of constricted air distribution on NOx emissions at unit 3 ( 125 MW power units, 420 t/h boiler) of Guixi power station, Jiangxi and puts forward the methads to decrease NOx emissions and the principle of boiler operation and regulation through analyzing NOx emissions state under real running condition. Based on boiler constdcted air distdbution, the expedment mainly tested the influence of primary air, excessive air, boiler load and milling sets (tertiary air) on NOx emissions and found its influence charactedstics. A degraded bituminous coal is simply adopted to avoid the test results from other factors.

关 键 词:煤粉 清洁燃烧 锅炉 氧化氮 释放规则

Influence of constricted air distribution on NO_x emissions in pulverized coal combustion boiler
WEI Feng ,ZHANG Jun ying ,TANG Bi guang ,ZHENG Chu guang. Influence of constricted air distribution on NO_x emissions in pulverized coal combustion boiler[J]. Journal of Coal Science & Engineering(China), 2003, 9(2): 79-83
Authors:WEI Feng   ZHANG Jun ying   TANG Bi guang   ZHENG Chu guang
Affiliation:National Laboratory of Coal Combustion, Huazhong University of Science and Technology, Wuhan 430074,China;School of Power and Machine Engineering, Wuhan University, Wuhan 430072, China
Abstract:This paper reports a field testing of full scale PCC (Pulverized Coal Combustion) boiler study into the influence of constricted air distribution on NO x emissions at unit 3 (125 MW power units, 420 t/h boiler) of Guixi power station, Jiangxi and puts forward the methods to decrease NO x emissions and the principle of boiler operation and regulation through analyzing NO x emissions state under real running condition. Based on boiler constricted air distribution, the experiment mainly tested the influence of primary air, excessive air, boiler load and milling sets (tertiary air) on NO x emissions and found its influence characteristics. A degraded bituminous coal is simply adopted to avoid the test results from other factors.
Keywords:NO x emissions  operation and regulate   pulverized coal combustion(PCC)