首页 | 本学科首页   官方微博 | 高级检索  
     


Structural Testing of Prestressed Concrete Girders from the Lake View Drive Bridge
Authors:Kent A. Harries
Affiliation:William Kepler Whiteford Faculty Fellow and Assistant Professor, Dept. of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA 152610. E-mail: kharries@pitt.edu
Abstract:On the evening of December 27, 2005, the fascia beam supporting the east-side parapet wall of the third span of the Lake View Drive Bridge failed under the action of dead load. This paper describes the structural testing and posttest forensic examination of two girders recovered from the partially collapsed Lake View Drive Bridge. The objective of this paper is to describe the tests conducted and report the observations. An interior and an exterior prestressed concrete adjacent box girder were tested to failure in flexure. Prior to testing, an extensive visual inspection was conducted to assess the extant condition of the 42-year-old girders. Following testing, the girders were sawcut near their failure regions to permit an extensive forensic investigation. Conclusions based on the pre- and posttest inspections and test results are presented. Recommendations intended to reinforce issues that need to be considered in the bridge inspection and rating process of similar structures are presented.
Keywords:Structural tests  Bridges, girder  Pennsylvania  Dead loads  Forensic engineering  