首页 | 本学科首页   官方微博 | 高级检索  
     


From the mouse to the mass spectrometer: detection and differentiation of the endoproteinase activities of botulinum neurotoxins A-G by mass spectrometry
Authors:Boyer Anne E  Moura Hercules  Woolfitt Adrian R  Kalb Suzanne R  McWilliams Lisa G  Pavlopoulos Antonis  Schmidt Jurgen G  Ashley David L  Barr John R
Affiliation:National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Highway, NE, Atlanta, Georgia 30341-3724, USA. aboyer@cdc.gov
Abstract:We have developed an assay (Endopep-MS) that detects the specific endoproteinase activities of all seven BoNT types by mass spectrometry (MS). Each BoNT type cleaves a unique site on proteins involved in neuronal transmission. Target peptide substrates based on these proteins identify a BoNT type by its enzymatic action on the substrate and the production of two peptide products, which are then detected by matrix-assisted laser desorption/ionization time-of-flight MS or liquid chromatography electrospray ionization MS/MS. We showed the ability to detect all seven toxin types in a multiplexed assay format. The detection limits achieved range from 0.039 to 0.625 mouse LD(50)/mL for toxin types A, B, E, and F in a buffer system. The Endopep-MS assay is the first to differentiate all seven BoNT types, is sensitive, specific, and has the potential to quantify toxin activity.