Development of a turbine meter for two-phase flow measurement in vertical pipes
Authors:Mark W. Johnson  Stuart Farroll
Affiliation:

Department of Mechanical Engineering, The University of Liverpool, Liverpool L69 3BX, UK

Abstract:The performance of a turbine meter in two-phase (water/air) flow in a vertical pipe is assessed. If the single phase (water) meter factor is used in two-phase flow, the total (water and air) flowrate is found to be underpredicted. The error can be as much as 12.5% at a void fraction of 25%. A technique for using measurements of the fluctuations in the turbine meter rotor velocity to determine void fraction (= air flowrate/total flowrate) is described. A single meter is then used to measure, using this technique, both the water flowrate to an accuracy of ± 2% and void fraction to an accuracy of ±0.02.
Keywords:turbine meter   two-phase flow   void fraction