首页 | 本学科首页   官方微博 | 高级检索  
     


A combined low power SAR capacitance-to-digital analog-to-digital converter for multisensory system
Authors:Hui Jiang  Ziqiang Wang  Chun Zhang  Hanjun Jiang  Zhihua Wang
Affiliation:1. Institute of Microelectronics, Tsinghua University, Beijing, China
Abstract:A combined successive approximation (SAR) capacitance-to-digital converter (CDC)/analog-to-digital converter (ADC) for biomedical multisensory system is presented in this paper. The two converters have same circuit blocks and can be exchanged by four switches. Capacitance or voltage from different sensing elements can be measured and converted to digital output directly. This single chip takes place of separated CDC and ADC so that the power consumption of the multisensory system is reduced. The asynchronous SAR circuit has low power and small area. A dynamic comparator with zero-static power is adopted. Switches are carefully designed to reduce the non-idealities of the converter. Several techniques, such as bootstrapped switches, bottom-plate sampling, dummy switches are used to improve the performance of the circuit. The CDC/ADC is fabricated in 0.18 μm CMOS process. Measurement results show that the ENOB of this 11 bits converter is 10.15 bits and its FOM is 45 fJ/conversion-step under 200 kHz sampling. The power consumption is 9.4 μW with 1.4 V power supply voltage and the core area is 0.1764 mm2.
Keywords:
本文献已被 SpringerLink 等数据库收录!