Adiabatic Calorimetric Decomposition Studies of 35 Mass% Hydroxylamine Hydrochloride/water
Authors:Lizbeth O. Cisneros  William J. Rogers  M Sam Mannan
Abstract:The HH (35 mass% hydroxylamine hydrochloride/water solution) and HH‐ind (stabilized 35 mass% hydroxylamine hydrochloride/water solution for industrial use) decomposition reaction has an onset temperature of ~145°C. The measured gas phase decomposition products are 0.25 mol N2 and 0.06 mol O2 per mol of hydroxylamine hydrochloride with small quantities of N2O and H2, and a trace amount of NO for a total noncondensable gas production of ~0.39 mol/mol of hydroxylamine hydrochloride. The reaction system is tempered by the evaporation of the solvent (water) and the reaction is drastically catalyzed by stainless and carbon steel.
Keywords:hydroxylamine hydrochloride  thermal decomposition  APTAC  metal contamination  adiabatic calorimetry
设为首页 | 免责声明 | 关于勤云 | 加入收藏