基于R600/R290混合制冷剂的立式冷冻箱的降温能力试验研究
引用本文:刘悦超,朱阳春,黄玉杰.基于R600/R290混合制冷剂的立式冷冻箱的降温能力试验研究[J].制冷与空调(北京),2022(1):43-46.
作者姓名:刘悦超  朱阳春  黄玉杰
作者单位:1.澳柯玛股份有限公司
摘    要:为优化以混合制冷剂为工质的立式冷冻箱制冷系统降温能力,对使用R600/R290混合制冷剂的立式冷冻箱在32℃环境温度下进行降温能力试验,研究混合制冷剂充注量、制冷剂各组分配比、毛细管流量及风机转速对其性能的影响.结果 表明:混合制冷剂充注量过大会削弱制冷系统降温能力,并使压缩机功率增加;增大毛细管流量、风机转速及混合制...

关 键 词:立式冷冻箱  混合制冷剂  R600/R290  降温能力

Cooling capacity experiment of vertical freezer based on R600/R290 mixed refrigerants
Liu Yuechao,Zhu Yangchun,Huang Yujie.Cooling capacity experiment of vertical freezer based on R600/R290 mixed refrigerants[J].Refrigeration and Air-conditioning,2022(1):43-46.
Authors:Liu Yuechao  Zhu Yangchun  Huang Yujie
Affiliation:,AUCMA Co., Ltd.
Abstract:In order to optimize the cooling capacity of the refrigeration system of vertical freezer with mixed refrigerants as working medium, the cooling capacity test on vertical freezer with R600/R290 mixed refrigerants is carried out at 32 ℃ ambient temperature.The effects of mixed refrigerant charge amount, refrigerant distribution ratio, capillary flow rate and fan speed on the performance are studied.The results show that if the charge amount of mixed refrigerants is too high, the cooling capacity of the refrigeration system will be weakened, and the power of compressor will increase.The cooling capacity of the refrigeration system can be improved by increasing the capillary flow rate, the fan speed and the proportion of R290 in the mixed refrigerants, and the cooling depth of the refrigeration system will be reduced by 0.7-3.3 ℃, in the meanwhile, the operation power of the refrigeration system will increase.The optimum system configuration is the unit with capillary flow rate of 5 L/min, refrigerant charge amount of 50 g and mass ratio of R600:R290 of 7:3, which meets the design requirements.
Keywords:vertical freezer  mixed refrigerants  R600/R290  cooling capacity