Antenna phase pattern measurements at millimeter wave frequencies using the differential phase method with only one power meter
Authors:Juha Mallat  Arto Lehto  Jussi Tuovinen
Affiliation:1. Radio Laboratory, Helsinki University of Technology, Otakaari 5 A, FIN-02150, Espoo, Finland
Abstract:The differential phase measurement method has been improved to need the use of only one power meter instead of three power meters. This enables accurate antenna phase pattern measurements with a simplified set-up, accompanied by the reduction in cost. All advantages of the differential phase measurement method are still also available, e.g. there is no need to phase lock oscillators or to use rotary joints. The measurement results for an antenna at 110 GHz are presented. A good agreement with earlier data was obtained.
Keywords:
本文献已被 SpringerLink 等数据库收录!