摘    要:以铬污染地下水为研究对象,分别用活性炭、零价铁、活性炭+零价铁作为反应介质,设计了渗透反应隔栅(PRB),对PRB治理六价铬污染地下水的可行性和有效性进行了试验研究,试验结果表明,活性炭对Cr(VI)有一定的吸附作用,零价铁对Cr(VI)有较强的还原作用,零价铁与活性炭配合作用时,二者的配比影响Cr(VI)的去除,零价铁所占质量分数越大,去除效果越好。零价铁、活性炭和石英砂质量分数分别为40%,4%和2%时,可以使Cr(VI)的质量浓度从100mg/L降低到0.05mg/L以下,达到《饮用净水水质标准》。采用PRB技术治理Cr(VI)污染地下水是可行的。

关 键 词:PRB  六价铬  零价铁  活性炭
文章编号:1009-2455(2005)02-0022-04
修稿时间:2004-07-19

A PRB Remediation Test of Cr-polluted Groundwater
MENG Fan-sheng,WANG Ye-yao,WANG Chun-xiang,CHEN Hong-bo. A PRB Remediation Test of Cr-polluted Groundwater[J]. Industrial Water & Wastewater, 2005, 36(2): 22-25
Authors:MENG Fan-sheng  WANG Ye-yao  WANG Chun-xiang  CHEN Hong-bo
Abstract:With Cr-polluted groundwater as the research subject, permeation reaction barriers (PRB) were designed with active carbon, Fe0, and active carbon plus Fe0 as reaction media respectively, with which the feasibility and effectiveness of the treatment of Cr-polluted groundwater by PRB were tested and studied. The results of the test show that active carbon has a certain adsorptive effect on Cr(VI) and Fe0 has a stronger reductive effect on Cr(VI); when Fe0 and active carbon act in combination, the proportioning of the two affects the removal rate ofCr(VI), i.e., the larger the mass fraction of Fe0 is, the better the removal effect will be. When the mass fractions of Fe0, active carbon and quartz sand are 40%, 4% and 2% respectively, the mass concentration of Cr(VI) can be reduced from 100 mg/L to 0.05 mg/L or below, which meets the requirement of water quality standard for fing drinking water. The result of the test shows that the use of the PRB technology in the treatment of Cr(VI)-polluted groundwater is feasible.
Keywords:PRB  Cr(VI)  Fe0  active carbon
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号