首页 | 本学科首页   官方微博 | 高级检索  
     


Energy and exergy efficiencies of a hybrid photovoltaic–thermal (PV/T) air collector
Authors:Anand S. Joshi  Arvind Tiwari
Affiliation:aCentre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
Abstract:In this communication, an attempt has been made to evaluate exergy analysis of a hybrid photovoltaic–thermal (PV/T) parallel plate air collector for cold climatic condition of India (Srinagar). The climatic data of Srinagar for the period of four years (1998–2001) has been obtained from Indian Metrological Department (IMD), Pune, India. Based on the data four climatic conditions have been defined. The performance of a hybrid PV/T parallel plate air collector has been studied for four climatic conditions and then exergy efficiencies have been carried out. It is observed that an instantaneous energy and exergy efficiency of PV/T air heater varies between 55–65 and 12–15%, respectively. These results are very close to the results predicted by Bosanac et al. [Photovoltaic/thermal solar collectors and their potential in Denmark. Final Report, EFP Project, 2003, 1713/00-0014, www.solenergi.dk/rapporter/pvtpotentialindenmark.pdf].
Keywords:Exergy   Hybrid photovoltaic–  thermal   Solar energy
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号