丰城电厂2号机组抗燃油酸值超标原因分析
引用本文:张昕宇.丰城电厂2号机组抗燃油酸值超标原因分析[J].热力发电,2004,33(8):73-74.
作者姓名:张昕宇
作者单位:江西电力试验研究院,江西,南昌,330006
摘    要:丰城电厂2号机组抗燃油酸值超标,其主要原因是旁路再生装置未投运及运行油温偏高。对此提出了相应的解决办法,并提出抗燃油系统的运行维护要点:(1)加强对运行油质的监督,特别是对酸值的监测;(2)旁路再生装置要连续运行,且吸附剂须及时更换;(3)应广洛控制油温。

关 键 词:汽轮发电机组  抗燃油系统  抗燃油酸值  滤油器  丰城电厂
文章编号:1002-3364(2004)08-0073-02

CAUSE ANALYSIS OF OVER-PROOF ACID VALUE FOR FIRE-RESISTANT OIL OF UNIT NO.2 IN FENGCHENG POWER PLANT
ZHANG Xin-yu.CAUSE ANALYSIS OF OVER-PROOF ACID VALUE FOR FIRE-RESISTANT OIL OF UNIT NO.2 IN FENGCHENG POWER PLANT[J].Thermal Power Generation,2004,33(8):73-74.
Authors:ZHANG Xin-yu
Affiliation:ZHANG Xin-yu
Abstract:The main causes leading to over-proof acid value of fire-resistant oil for unit No.2 in Fengcheng Power Plant are the by-pass regenerative facility being not put into operation, and the oil temperature in operation is comparatively high. The corresponding resolving measures have been put forward, and main points for attention in operation and maintenance of the fire-resistant oil system being given, namely:(1) strengthening oil quality supervision in operation, especially to monitor the acid value of said oil; (2) the by-pass regenerative facility has to be continuously in operation, and the absorbents have to be timely replaced; (3) the oil temperature has to be strictly controlled.
Keywords:fire-resistant oil  acid value  precise oil filter  filtration materials  