Abstract: | This paper describes an experimental and a semi-empirical study on the impingement cooling characteristics of heat sinks with longitudinal fins of a type suitable for LSI packages. The experiments were performed with a variety of different fins. To enhance impingement cooling, one long rectangular inlet orifice (slit) over the center of the heat sink was found to offer the best structure. The optimum orifice width is about 1/6 of the base width of the heat sink. The thermal resistance at a fixed volumetric flow rate and orifice width varies little with size of the gap between the fin tops and inlet orifice, but gaps near 2 mm slightly lower the resistance. Correlations are proposed between the thermal resistance of the heat sink and the geometry of the longitudinal fins. The accuracy of the predicted thermal resistances was found to be within ±25% of the experimental data. © 1997 Scripta Technica, Inc. Heat Trans Jpn Res, 25(8): 537–553, 1996 |