首页 | 本学科首页   官方微博 | 高级检索  
     

电选机电场强度与相对湿度之间的关系
引用本文:何家宁,Daniel Tao,张宗华,马武兴,任伟. 电选机电场强度与相对湿度之间的关系[J]. 金属矿山, 2006, 0(6): 27-29,39
作者姓名:何家宁  Daniel Tao  张宗华  马武兴  任伟
作者单位:昆明理工大学;美国肯塔基大学;美国肯塔基大学;昆明理工大学
基金项目:美国肯塔基州科学技术创新商业化投资基金
摘    要:为了研究电选机高压静电分选腔的电场强度与相对湿度之间的关系,设计了能产生高达100%相对湿度的高湿度发生器,并进行了不同相对湿度下粉煤灰电选效果的实验研究。结果表明,随着相对湿度的增加,电选机的分选效果变差,直至电场被击穿而使电选机无法正常工作。根据实验结果,引入相对湿度系数五,对电选机高压静电分选腔电场强度的设计公式进行了修正,以求电选机高压静电分选腔的设计更为科学。

关 键 词:电选机  高压静电分选腔  电场强度  相对湿度  高湿度发生器
收稿时间:2006-04-15
修稿时间:2006-04-15

Relationship between Electric Field Intensity and Relative Humidity of Electrostatic Separator
He Jianing,Daniel Tao,Zhang Zonghua,Ma Wuxing,Ren Wei. Relationship between Electric Field Intensity and Relative Humidity of Electrostatic Separator[J]. Metal Mine, 2006, 0(6): 27-29,39
Authors:He Jianing  Daniel Tao  Zhang Zonghua  Ma Wuxing  Ren Wei
Affiliation:1. Kunming University of Science and Technology; 2. University of Kentucky, USA
Abstract:To study the relationship between the electric field intensity and the relative humidity of the high voltage static separation chamber of electrostatic separator, a high humidity generator that can produce 100% relative humidity was developed and used in the test on the electrostatic separation of powder coal under various humidities. The results showed that, with the increase of relative humidity, the separation effect of electrostatic separator became worse until the electric field was brokendown and the separator could not keep normal work. Based on the test results, a coefficient f2 of relative humidity was introduced in the modification of the design equation for the electric field intensity of high voltage static separation chamber of electrostatic separator, so as to make the design of the separator more scientifically.
Keywords:Electrostatic separator   High voltage electrostatic separation chamber   Electric field intensity   Relative humidity   High humidity generator
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号