能谱-剂量转换法用于环境辐射剂量测量
引用本文:曹蕾,李德红,杨扬,黄建微,张晓乐,张璇,成建波.能谱-剂量转换法用于环境辐射剂量测量[J].同位素,2022,35(4):297-303.
作者姓名:曹蕾  李德红  杨扬  黄建微  张晓乐  张璇  成建波
作者单位:中国计量科学研究院,北京100013;北京师范大学,北京100875
摘    要:为准确测量环境水平剂量率,基于无卷积全谱转换法,通过测量X/γ能谱和剂量率,开展能谱-剂量转换系数求解并实现能谱-剂量的转换。结果表明,能谱-剂量法计算剂量率与实测剂量率的残差近似为0,证明该方法在能谱-剂量求解过程自洽;在137Cs、60Co标准参考辐射场下的剂量率线性测试结果与标准值的最大相对误差为±10%,表明无卷积全谱转换法用于能谱-剂量转换系数的求解可行。

关 键 词:能谱-剂量  G(E)函数法  无卷积全谱转换法  高纯锗谱仪  

Energy Spectrum to Dose Conversion Method Used in Environmental Radiation Dose Measurement
CAO Lei,LI Dehong,YANG Yang,HUANG Jianwei,ZHANG Xiaole,ZHANG Xuan,CHENG Jianbo.Energy Spectrum to Dose Conversion Method Used in Environmental Radiation Dose Measurement[J].Isotopes,2022,35(4):297-303.
Authors:CAO Lei  LI Dehong  YANG Yang  HUANG Jianwei  ZHANG Xiaole  ZHANG Xuan  CHENG Jianbo
Affiliation:National Institute of Metrology, Beijing 100013, China;Beijing Normal University, Beijing 100875, China
Abstract:In order to accurately measure the environmental level dose rate, based on the G(E) function method and conversion of complete spectra without deconvolution method, the energy spectrum and dose rate of X/γ ray was measured for calculating spectrum-dose conversion coefficient. And finally the conversion of energy spectrum to dose rate is realized. The residual difference between the calculated dose rate by the energy spectrum-dose method and the measured dose rate value is approximately 0, which proves that the method is self-consistent. Experiments have been conducted in 137Cs and 60Co radiation fields, and the maximum relative error of dose rate is ±10%, which proves that the G(E) function method and Conversion of complete spectra without deconvolution method are feasible for energy spectrum-dose conversion.
Keywords:energy spectrum to dose  G(E) function method  conversion of complete spectra without deconvolution method  high purity germanium detector  