Time resolved measurement of pulsating flow using orifices
Authors:K. Doblhoff-Dier,K. KudlatyM. Wiesinger,M. Grö  schl
Affiliation:
  • a Institute of Applied Physics, Vienna University of Technology, Wiedner Hauptstrasse 8/134, A-1040 Vienna, Austria
  • b AVL List GmbH, Hans-List-Platz 1, A-8020 Graz, Austria
  • Abstract:This article reviews the theoretical background of the measurement of pulsating flow using orifices as flow to pressure transducers, providing a synopsis of work done in this field. Special attention is paid to the temporal inertia and the applicability of expressions thereof given in the literature. Other factors influencing the measurement, such as changing flow profiles and the effect of connection tubes between the pressure sensor and the orifice are discussed. An experiment was performed to investigate the applicability of an equation taking reverse flow and temporal inertia into account for the measurement of pulsating flow with relative pulsation amplitudes around 1 and frequencies up to 50 Hz. It was found that the suggested equation may give tolerable results if the ratio of the pulsating part of the velocity to the angular frequency times orifice diameter is not too high. For high ratios, however, the results could not be explained by the suggested equation.
    Keywords:Flow metering   Pulsating flow   Orifice