首页 | 本学科首页   官方微博 | 高级检索  
     

阻尼矩阵选取对核电厂结构地震响应的影响分析
引用本文:李小军,侯春林,潘蓉,周国良,杨宇.阻尼矩阵选取对核电厂结构地震响应的影响分析[J].振动与冲击,2015,34(1):110-116.
作者姓名:李小军  侯春林  潘蓉  周国良  杨宇
作者单位:1. 北京工业大学建筑工程学院,北京,100124; 2.国家环保总局核与辐射安全中心,北京 100082; 3.中国地震局地球物理研究所,北京100080
基金项目:国家重点科技攻关项目(2011ZX06002-10-15,2011ZX06002-10-16);国家自然科学基金重大研究计划资助项目(91215301);北京市属高等学校创新团队建设提升计划资助
摘    要:已有研究表明时程动力法中阻尼矩阵的确定对复杂结构工程的地震响应有明显的影响,而核电厂安全相关结构在抗震分析时通常采用时程动力法。为研究阻尼矩阵的选取对核电厂结构的地震响应的影响,从比例阻尼拟合的精度出发,基于结构不同振型对结构产生的影响程度入手,建立更为精确的结构阻尼模型,即等效比例阻尼,并进一步考虑结构自振特性以加权最小二乘法拟合确定等效比例阻尼系数,提出了核电厂结构地震响应分析相应的计算方法。计算结果表明,该方法较传统比例阻尼的方法更接近精确解,是核电工程抗震分析的一个实用参考应用。

关 键 词:核电厂    抗震分析    阻尼模型    时程动力法  

Effect of damping matrix selection on seismic response of nuclear power plant structures
LI Xiao-jun,HOU Chun-lin,PAN Rong,ZHOU Guo-liang,YANG Yu.Effect of damping matrix selection on seismic response of nuclear power plant structures[J].Journal of Vibration and Shock,2015,34(1):110-116.
Authors:LI Xiao-jun  HOU Chun-lin  PAN Rong  ZHOU Guo-liang  YANG Yu
Affiliation:1.The College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, 100124, China; 2.Nuclear and Radiation Safety Centre,Ministry of Environmental Protection of the People’s Republic of China, Beijing 100082, China; 3.Institute of Geophysics, China Earthquake Administration, Beijing 100081,China
Abstract:It shows that determination of damping matrix in the dynamic time-history analysis method strongly affects the seismic response of complex engineering structures, and the safety related structures of nuclear power plant in dynamic analysis usually adopts the dynamic time-history analysis method. To study the effect of determination of damping matrix on the seismic response of nuclear power plant structure, we consider the proportional damping fitting accuracy of nuclear power plant structure, and the influence of different shape of structure based on structural damping, to set up a more precise model, an equivalent proportional damping model. Furthermore, a corresponding method of the seismic response analysis of the nuclear power plant structure is proposed by taking consideration of structural vibration characteristics, which is, determining the proportional damping coefficient by weighted least square fitting method. The application and analysis show that the method is more consistent with the exact solution than the method with traditional damping coefficient, and it is suitable for the seismic response of nuclear power plant structure.
Keywords:nuclear power plant  seismic analysis  damping model  time-history method