炕-地组合供暖末端室内热环境及其热均匀性评价实验研究
引用本文:李涛,毛前军,王登甲,刘艳峰.炕-地组合供暖末端室内热环境及其热均匀性评价实验研究[J].暖通空调,2022(1):136-142,131.
作者姓名:李涛  毛前军  王登甲  刘艳峰
作者单位:武汉科技大学;武汉科技大学城市建筑学院;西安建筑科技大学
基金项目:西部绿色建筑国家重点实验室开放基金资助项目(编号:LSKF202105)。
摘    要:为满足西北村镇居民冬季室内分时分区热需求,提出了一种炕-地组合供暖末端形式,对组合末端4种运行模式下的室内热环境营造效果进行了对比实验研究.掌握了组合末端不同运行模式下室内热环境昼夜变化特征,对比分析了温度空间不均匀性和辐射不均匀性.结果 表明:组合末端单独运行时均无法同时满足昼夜室内舒适温度要求,且温度空间均匀性和辐...

关 键 词:炕-地组合供暖末端  室内热环境  热均匀性  分时分区热需求  运行模式  温度空间均匀性  辐射均匀性  村镇供暖

Experimental study on indoor thermal environment and thermal uniformity evaluation of combined floor and Kang heating terminal
Li Tao,Mao Qianjun,Wang Dengjia,Liu Yanfeng.Experimental study on indoor thermal environment and thermal uniformity evaluation of combined floor and Kang heating terminal[J].Journal Heating Ventilating and Airconditioning,2022(1):136-142,131.
Authors:Li Tao  Mao Qianjun  Wang Dengjia  Liu Yanfeng
Affiliation:(Wuhan University of Science and Technology,Wuhan;Xi’an University of Architecture and Technology,Xi’an)
Abstract:In order to meet the temporal-spatial partition thermal demand of residents in northwest villages and towns in winter,a combined floor and Kang heating terminal is proposed,and a comparative experimental study is carried out on the indoor thermal environment construction effect of the combined terminal in four operating modes.The characteristics of day and night of indoor thermal environment in different operating modes of the combined terminal are mastered.The temperature space heterogeneity and radiation heterogeneity are compared and analysed.The results show that when the combined terminal is operated alone,it could not meet the requirements of indoor comfortable temperature of day and night at the same time,and the uniformities of temperature space and radiation are poor.When running together,the indoor thermal environment has the best effect,but the indoor temperature is higher than the indoor comfortable temperature,resulting in a certain heat waste.When running alternately,it can better meet the requirements of indoor comfortable temperature of day and night with the better thermal uniformity,so it has significant advantages.This study finds the feasibility of the combined terminal application and its suitable operation mode,which provides the proof for the improvement of indoor thermal environment by applying the combined terminal to the buildings in northwest villages and towns.
Keywords:combined floor and Kang heating terminal  indoor thermal environment  thermal uniformity  temporal-spatial partition thermal demand  operation mode  temperature space uniformity  radiation uniformity  village and town heating