定子冷却水中断对发电机造成的损坏及修复
引用本文:王宾,辛文达.定子冷却水中断对发电机造成的损坏及修复[J].广东电力,2000,13(5):69-71.
作者姓名:王宾  辛文达
作者单位:沙角发电总厂,广东,东莞,523908
摘    要:对沙角C电厂内冷水中断事故及其对发电机造成的损坏作了介绍,经分析,造成了定子绕组继水后出现振动过大的主要原因是端部固定方式较薄弱,无法承受在一定的温升时所产生的热膨胀,事故后,厂家决定对发电机绕组端部进行临时性的加固,情况已经明显改善。

关 键 词:发电机  定子绕组  冷却系统  故障
修稿时间:1999-11-29

Generator damage caused by interruption of stator cooling water and repair after
WANG Bin,XIN Wen-da.Generator damage caused by interruption of stator cooling water and repair after[J].Guangdong Electric Power,2000,13(5):69-71.
Authors:WANG Bin  XIN Wen-da
Abstract:This paper introduces the generator damage caused b y interruption of cooling water in Shajiao C Power Station. It reaches a conclus ion through analysis that the fixing of the stator end-winding was comparativel y weak and unable to withstand the thermal expansion at a certain temperature ri se, which became the major cause for the excessive vibration after the interrupt ion. Temporary reinforcement on the generator end-winding was made and satisfac tory results were obtained.
Keywords:generator  stator winding  vibration  temperatu re rise