首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental and simulation studies on the effect of suction opening orientation on solar vertical chimney
Authors:L. Madan Ananda Kumar  V. Sivaramakrishnan  M. Premalatha  M. Vivekanandan
Affiliation:1. Department of Mechanical Engineering, K. Ramakrishnan College of Engineering, Samayapuram, Tiruchirappalli 621112, India;2. Roever Engineering College, Perambalur 621212, India;3. National Institute of Technology, Tiruchirappalli 620015, India;4. Uttam Industrial Engg. Ltd, Trichy 620018, India
Abstract:The zero energy building considered is a single storey building in Tiruchirappalli city retrofitted with various green features. This study investigated the effect of a suction opening orientation on a vertical solar chimney (VSC), integrated into a one-storey building. It was designed, manufactured and tested through selection of different suction openings for the entry of air, including right, left, front, back, both right and left and both front and back sides. Genetic algorithm (GA) calculates maximum air flow rate for a building with VSC for better suction opening, in Tiruchirappalli's dry, environmental conditions. GA is a useful technique for finding an improved suction opening specifically in the presence of a host of independent parameters which are large. The obtained results are related to fluid flow temperature distribution along the chimney, mass flow rate and air change per hour. The findings between the GA and the experimental results show sound agreement.
Keywords:Solar chimney  natural ventilation  genetic algorithm  zero energy building
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号