首页 | 本学科首页   官方微博 | 高级检索  
     


Performance of Unreinforced Masonry Walls Retrofitted with Externally Anchored Steel Studs under Blast Loading
Authors:Badr M. Abou-Zeid  Wael W. El-Dakhakhni  A. Ghani Razaqpur  S. Foo
Affiliation:1Senior Engineer, Structural Dept., SNC-Lavalin Group, Heliopolis, Cairo, Egypt; formerly, Ph.D. Candidate, Dept. of Civil Engineering, McMaster Univ., Hamilton, L8S 4L7, Ontario, Canada. E-mail: badr.abouzeid@snclavalin.com
2Martini, Mascarin and George Chair in Masonry Design, Dept. of Civil Engineering, McMaster Univ., Hamilton, L8S 4L7, Ontario, Canada (corresponding author). E-mail: eldak@mcmaster.ca
3Professor, Dept. of Civil Engineering, McMaster Univ., Hamilton, L8S 4L7, Ontario, Canada. E-mail: razaqpu@mcmaster.ca
4Senior Engineer (Risk Management), Real Property Branch, Public Works and Government Services, Canada. E-mail: simon.foo@pwgsc.gc.ca
Abstract:Six full-scale concrete masonry walls were tested under free-field blast loading using different charge sizes up to 250?kg of ammonium nitrate/fuel oil (ANFO) and at a constant stand-off distance of 15.0?m to cover a wide range of expected damage levels. Five walls were retrofitted with cold-formed steel studs anchored to the wall backs and were compared to the remaining as-built wall. Significant enhancement to the out-of-plane blast resistance of the retrofitted walls, compared to the as-built wall, was observed. This enhancement is attributed to the development of a tied-arch action in the retrofitted walls in which the masonry forms a compression strut while the steel studs serve as the tie. A simplified single-degree-of-freedom model was used to analyze the experimental results, and the model results agreed well with the observed damage levels and the resistances of the walls. In addition, the effectiveness of the proposed retrofit technique was evaluated in terms of strength enhancement and wall deflection reduction. The test results were also compared with those predicted by available blast damage assessment models for unreinforced masonry walls. However, it was found that available models, which do not account for the tied-arch mechanism, greatly underestimate the actual blast capacity of the retrofitted walls because of the assumption of a tensile flexural failure mode. Additionally, the proposed retrofit technique shifts the mode of failure from flexure to shear.
Keywords:Blast loads  Concrete  Masonry  Experimentation  Shear failures  Studs  Walls  Rehabilitation  