首页 | 本学科首页   官方微博 | 高级检索  
     

离子膜法烧碱装置自动控制系统的优化
引用本文:李刚. 离子膜法烧碱装置自动控制系统的优化[J]. 氯碱工业, 2014, 0(3): 38-41
作者姓名:李刚
作者单位:金川集团股份有限公司化工厂,甘肃金昌737100
摘    要:介绍了和利时公司MACSV控制系统在离子膜法烧碱生产过程中的应用,阐述了工艺流程及硬件配置。分析了各工序主要自动控制过程,对脱硝盐水系统pH值、电解槽出口气相总管压力、电解液浓度、氢气压缩机出口压力及合成炉氯氢流量比值等复杂控制系统进行优化,经过调试运行,各项技术指标达到设计要求,整个离子膜法烧碱系统实现自动控制。

关 键 词:离子膜法烧碱  自动控制  优化

Optimization on automatic control system for ion-exchange membrane caustic soda facilities
Affiliation:ld Gang (Chemical Plant, Jinchuan Group Co. Ltd. , Jinchang 737100, China)
Abstract:The application of control system MACSV of HollySys Co. in the production of ion-exchange membrane caustic soda was introduced. The process flow and the hardware configuration were introduced. The main automatic control processes for each procedure were analyzed. The complex automatic control systems for the pH value of desulfated brine, for the pressure of electrolyzer outlet gas-phase manifold, for electrolyte concentration, for the pressure of hydrogen compressor outlet, and for the flow ratio of chlorine to hydrogen feeding to synthesis furnace, were optimized. each technical index met design requirements, and automatic control caustic soda systemn was realized. After commissionng and regulation, of the whole ion-exchange membrane
Keywords:ion-exchange membrane caustic soda  automatic control  optimization