首页 | 本学科首页   官方微博 | 高级检索  
     


The influence of applied tensile stress on power loss in Co-rich amorphous Co-Fe-Si-B ribbons with induced magnetic anisotropy
Authors:Nielsen  H Nielsen  K Nielsen  O
Affiliation:Posts and Telegraphs of Denmark, Denmark;
Abstract:The influence on power loss PTof applied tensile stress σ in amorphous (Co0.89Fe0.11)72Mo3Si15B10(lambda_{s} > 0) and Co73Mo2Si15B10(lambda_{s} < 0) ribbons with different induced magnetic anisotropy Kuis reported. The losses are measured under sinusoidal flux conditions atf = 50Hz,J_{max} = 0.57T and atf = 400Hz,J_{max} = 0.10T. Measurements are carried out on samples in a stress-relieved state and with magnetic anisotropies induced by stress or field annealing. Atf = 50Hz, a minimum m Ptversus σ is observed. The σ-value (sigma_{min}) corresponding to the minimum PTincreases with increasing |Ku|. Atf = 400Hz, a minimum in PTversus σ is observed in the samples with induced magnetic anisotropy, whereassigma_{min} = 0in the stress-relieved samiales. However, no correlation between andsigma_{min}and Kuis possible from the present data.
Keywords: