首页 | 本学科首页   官方微博 | 高级检索  
     


Feasibility assessment of magnetic resonance-thermometry on pancreas undergoing laser ablation: Sensitivity analysis of three sequences
Affiliation:1. Unit of Measurements and Biomedical Instrumentation, Center for Integrated Research, Università Campus Bio-Medico di Roma, Via Álvaro del Portillo, 21, Rome 00128, Italy;2. Unit of Radiology, Center for Integrated Research, Università Campus Bio-Medico di Roma, Via Álvaro del Portillo, 21, Rome 00128, Italy;3. Unit of Radiology, AORN A. Cardarelli, Via Cardarelli, 9, Naples 80131, Italy;1. Department of Surgical Sciences, Università di Cagliari, Via Binaghi 4, 09121 Cagliari, Italy;2. Department of Management and Production Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy;3. Thermodynamics Division, Istituto Nazionale di Ricerca Metrologica, Strada delle Cacce 91, 10135 Torino, Italy;4. CNR Institute of Acoustics and Sensors “O. M. Corbino”, Via Fosso del Cavaliere 100, 00133 Roma, Italy;1. School of Information Science and Technology, Yunnan Normal University, Yunnan 650092, China;2. School of Tourism and Geographical Science, Yunnan Normal University, Yunnan 650092, China;3. GIS Technology Research Centre of Resource and Environment in Western China, Ministry of Education, Yunnan Normal University, Yunnan 650092, China;4. Academic Administration, Yunnan Normal University, Yunnan 650500, China;5. Harbin ShuangLong Aeronautical Engineering Limited Company, Harbin 150080, China;1. School of Automation Science and Electrical Engineering, Beihang University, Beijing, China;2. Beijing Simulation Center, Beijing, China
Abstract:Laser ablation (LA) is a minimally invasive technique for the treatment of tumors as an alternative to surgical resection. The light absorbed by tissue is converted into heat, and causes irreversible cell damage when temperatures higher than 60 °C are reached. The knowledge in real time of temperature may be particularly beneficial for adjusting laser settings applied during treatment and to be notified in real time about its end-point. As a consequence, several techniques for temperature monitoring within the tissue have been investigated along the last decades. In the field of LA, particularly attractive are non-invasive methods. Among these techniques, thermometry based on the analysis of Magnetic Resonance Imaging (MR-thermometry) has gaining large acceptance in this field. MR-thermometry allows estimating the temperature variation thanks to the thermal dependence of several MRI parameters, among others the most promising are T1 relaxation time, and proton resonance frequency shift.The aim of this study is to assess the sensitivity of MRI thermometry using three T1-weighted sequences (i.e., Inversion Recovery Turbo-FLASH, IRTF, Saturation Recovery Turbo-FLASH, SRTF, and FLASH) using an 1.5-T MR scanner on healthy swine pancreases undergoing LA. The reference temperature was measured by MRI-compatible fiber optic sensors (fiber Bragg grating sensors). The sensitivity of the proposed techniques was estimated and compared. The thermal sensitivity of the three sequences was ?1.47 ± 0.08 °C?1, ?0.95 ± 0.05 °C?1, and ?0.56 ± 0.04 °C?1 for IRTF, SRTF and FLASH, respectively. Results show that the proposed technique may be adequate for temperature monitoring during LA.
Keywords:MR-thermometry  Fiber Bragg grating sensors  Laser ablation  Sequences  Pancreas  Thermal sensitivity
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号